Eazychem Call us today (+44) 01403 801010

Products

eazy BWT-1

1001

Boiler water treatment

eazy BWT-1 is a liquid treatment designed to inhibit scale formation and corrosion within the marine boiler circuit.

Contact us for Material Safety Data Sheet PDF
  • Description
  • Application
  • Directions
  • Legal

Description

eazy BWT-1 is a uniquely blended liquid boiler treatment programme designed to inhibit scale formation and corrosion within the boiler circuit. The product contains additives to inhibit scale when hard water breakthrough occurs, inhibit corrosion in the boiler circuit as well as the condensate lines and scavenge minor traces of oil. The conditioned feed water will form a loose, non-adhering sludge that can easily be removed by blow down.

The polymeric phosphate dispersants and corrosion inhibitors meet FDA requirements and the product does not contain hydrazine.

Application

It is recommended that product be used with good quality feed water and dosed into the feed water line after the feed water re-circulation off take. This should be done by diluting with distilled water or condensate and dosed over a 24 hour period.

Directions

Dosage
Initial dosage depends on the prevailing boiler condition and the quality of the feed water. In general the dosage rate should be 2.5 to 5.0 litres per tonne of water.

Maintenance dosage should be 0.5 to 2.5 litres per day depending on test results.

Testing
Eazychem boiler water test kits are used to monitor dosage and control parameters. These simplified tests are listed on the dosage and control charts. It is recommended that regular testing be carried out to ensure that levels of treatment and control are correct.

Blow Down
Blow down may be necessary to reduce the amount of dissolved and suspended solids. This should be done in accordance with the boiler manufacturer’s instruction.